Símbolo Fondo Science

Contacte para más información en el teléfono +34 629 829 605

Revista Española de Artroscopia y Cirugía Articular

Asociación Española de Artroscopia (AEA)

ISSN online: 2443-9754 (es)
ISSN impreso: 2386-3129 (es)
Vol. 18. Fasc. 2. Núm. 45. Octubre 2011
DOI: (sin asignar)
Recibido: Octubre 2011
Aceptado: Octubre 2011
Originales

Comparación de los resultados clínicos de la reparación del manguito rotador en doble fila frente a fila simple en pacientes con compensación laboral

Comparison of the clinical outcomes of arthroscopic single versus double-row rotator cuff repair in workers’ compensation patients

Cuad Artroscop. 2011;18(2):38-45

Resumen: 

El propósito de este estudio es analizar los resultados de la reparación artroscópica de la rotura del manguito rotador en fila simple (FS) frente a la doble fila (DF) en pacientes con compensación laboral. Ciento cuarenta pacientes se sometieron a la reparación artroscópica de una rotura del manguito rotador. Los 104 pacientes que cumplieron los criterios de inclusión se dividieron en dos grupos, dependiendo del tamaño lesional: grupo 1: roturas menores de 3 cm (n = 54), que se repararon con FS, y grupo 2: roturas mayores de 3 cm (n = 50), que fueron reparadas en DF. No hubo diferencias significativas entre los grupos en periodo de rehabilitación, periodo de baja laboral, movilidad activa al final de la rehabilitación, dolor, vuelta al trabajo, incapacidades laborales ni reintervenciones. Sólo la duración de la cirugía fue estadísticamente diferente. Nuestros resultados a corto plazo sugieren que la reparación artroscópica de roturas pequeñas y medianas del manguito (<3 cm) mediante FS proporciona resultados clínicos comparables con la reparación en DF de roturas grandes y masivas (>3 cm) en pacientes con compensación laboral. La ausencia de diferencias significativas cuando el tamaño de la lesión al principio era diferente es un resultado a favor de la reparación en DF.

Abstract: 

The purpose of this study was to analyze the outcomes of arthroscopic single versus double row repair of the rotator cuff tears in workers’ compensation patients. One hundred and forty workers’ compensation patients underwent arthroscopic repair of a full-thickness rotator cuff tear, but only 104 patients passed the inclusion criteria. They were divided into two groups, depending on the lesion size. In Group 1, tears <3cm (n=54), simple row (SR) technique was performed, and in group 2, tears>3cm (n=50), double row (DR) technique was performed. There were no statistic differences between groups in terms of period of rehabilitation, period of sick leave, active ROM at the end of the rehabilitation, pain, return to preoperative work, work incapacities nor reoperations. Only the duration of the surgery was statistically different. Our short-term outcomes suggest that arthroscopic SR repair of small and medium tears (<3cm) provides comparable clinical outcomes to DR repair in large and massive tears (>3cm) in workers’ compensation patients. The absence of statistic differences when the lesion size at the beginning was different is an outcome in favour of DR repair.

Cita bibliográfica

García Rellán JE, Sánchez Alepuz E, Carratalá Baixauli V, Castro R, Calero Ferrandiz RComparación de los resultados clínicos de la reparación del manguito rotador en doble fila frente a fila simple en pacientes con compensación laboral. Cuad Artroscop. 2011;18(2):38-45. doi: DOI: (sin asignar)

Descargar artículo: 

Icono PDF fs_18245.fs1110006-comparacion-resultados-clinicos.pdf

Licencia: 

Este contenido es de acceso abierto (Open-Access) y se ha distribuido bajo los términos de la licencia Creative Commons CC BY-NC-ND (Reconocimiento-NoComercial-SinObraDerivada 4.0 Internacional) que permite usar, distribuir y reproducir en cualquier medio siempre que se citen a los autores y no se utilice para fines comerciales ni para hacer obras derivadas.